Air Conditioning and Heating Services in Benton IL
Charlie’s Air Conditioning & Heating has provided Benton, IL with excellent service for over 30 years. We specialize in heating and air conditioning products and services, as well as insulation upgrades.
Read our excellent reviews and find out why your Southern Illinois neighbors consider us to be their nearby heating and air company in Benton, IL.
Local Reviews
for Benton, IL
Our Reviews by City
Great Service!
Danae - Benton, IL 62812
Great service
Randy - Benton, IL 62812
Great service!
Danae - Benton, IL 62812
I called with my problem and they were there to fix quickly!
Great service
Randy - Benton, IL 62812
Shawn worked his tail off to get my air conditioner up and running.
Great
Juanita - Benton, IL 62812
He did a good job and he did it sweet personality
Great service, knowledgeable, friendly, and respectful.
Salina - Benton, IL 62812
I have lived at this residence for 10 years. Phil P is by far the best contractor of any sort I have ever had come to my home.
Great service
Lori - Benton, IL 62812
Phil was knowledgeable and professional!! Great, timely, affordable and friendly service!! Thank you
Quick effective and inexpensive
Butcher - Benton, IL 62812
Phil arrived on time and performed the work needed to get my a/c running quicker than I expected and did not over charge me!
Regular checkup.
Juanita - Benton, IL 62812
Shawn did a great job! Polite and honest!
Great service
Randy - Benton, IL 62812
Phil was very knowledgeable
Great Service
Danae - Benton, IL 62812
I love that they send you a picture of the tech and his name before they arrive and that you can track when they will be there! No having to wait around. The tech was very knowledgeable and professional.
Very efficient; Steve was helpful, friendly, and informative. Charlie's has continuously provided great service.
Juanita - Benton, IL 62812
I'm so glad that I switched to Charlie's!!
He did a great job, very polite.
Juanita - Benton, IL 62812
I really appreciated his honesty.
All around excellent
Potts - Benton, IL 62812
This company is always puts the customer first. Technicians are very knowledgeable, proficient while maintaining excellent customer relations.
Justin T.
PCSA 2022 Heating Check Up Free w/ Install. System is heating well at this time, filter is changed and temperature rise is acceptable.
Justin T.
System is heating at this time. System had a clogged drain line, pressure switch hose was dirty inside causing switch to trip when not needed and burners need thorough maintenance but are clean at this moment. Pilot light is lit and holding at this time. System also needs a filter and is run in without one. Temp rise is 37 degrees which is acceptable.
Shawn C.
Pumped down unit and pulled out coil, called Benoist with no response so far. Calling winair to order universal azure motor for replacement tentatively looking at Monday.
Shawn C.
Complaint furnace not shutting off Was just out here. Waived diag. This time caught thermostat sticking. Replaced thermostat unit operating as designed
Shawn C.
Complaint: No Heat Blower was running continuously due to the fan being set to the “on” position. 2 out of 3 heat strips equipped. Both strip heaters coming on. Looks like someone spliced the wire coming into the furnace and reduced the conductor size. A note was made by a previous technician to not equip all 15 kw unless splice was fixed. I would stand by that but also add that in a single wide I don’t believe this customer needs more than 10 kw which I let her know. Unit heating at this time
Justin T.
PCSA 2022 Heating Check Up Renewal. Gas furnace is heating efficiently at this time, temperature rise is acceptable, and all hoses and drains are clean.
Shawn C.
Complaint: No Heat Nothing Coming On Bad x13 motor. Would have to pull coil to replaced blower. 2 man job. Steve will work on quote
Shawn C.
Charge and equipment look good. Furnace checks good. Need to patch ceiling asap. It’s sucking hot humid attic air into return. We will come back with insulation and an insulated patch to put around pipe and cover hole in ceiling. Then a new drop tile can go in
Pete F.
Quote for AC
Steve R.
PCSA 2022 a/c check up free w/ install filter looked great, changed by customer. Checked coil and electrical indoors, flushed drain. Checked charge, superheat chart called for 12 degrees, had 27. Added a few ounces, got superheat to 11 degrees. Setup visit 9/9 to check charge
Shawn C.
Complaint no cool, did 2022 summer PCSA on both units Bad ECM fan motor on house unit. I left Valerie a message on her cell letting her know what is going on. Steve has told me he will be out here in the morning with the correct fan motor to change it for her. All other checks were good across both systems. They have been cleaned. We just need to check the charge on the house unit once motor is replaced. Putting job on hold for now 8/10/22 Steve returned and replaced motor, checked charge unit is running great
Shawn C.
Pull thermostat wire Thermostat wire pulled. System cooling at this time, unit next to it frozen up. Added 2 lbs of r-22 and leak stop.
Shawn C.
Outside unit doesn't come on. Broken wire from thermostat to furnace. No continuity when twisting R and Y together. Customer may call us to run new wire
Shawn C.
Credited diag no charge, cemented around pipe
Shawn C.
Filter drier replaced vacuum pulled to 400 microns charged with 421A refrigerant 6.5 lbs. thermostat wire will not pull. Need to go with my original plan of dropping stat wire through soffit. Drain unclogged on unit that had filter drier repair, compressor burnout kit added to unit with drier repair. Shorted unit in back of building not operating at this time, unit with filter drier replacement running and cooling at this time
Shawn C.
Added an hour for 3 diagnostics. Changed fan motor. Unit up front has a liquid line restriction Another unit needs stat wire replaced going outside has a 24v short
Gerson C.
Wires need redone so they are not exposed no charge . Tidy-up unit.
Gerson C.
Complaint indoor unit making noise. Replaced blower motor
Shawn C.
Complaint no a/c Had to drill shaft out to save fan blade. Fan motor replaced
Shawn C.
PCSA 2022 a/c check up prepaid All checks are good on ac. 20x20 won’t fit, we will continue to wash each at this time
Gerson C.
1987 trane poor compressor .R-22 Attic A/h round grills poor duct. Needs estimate.
Gerson C.
No AC - unit clicked like it was gonna come on but no blower inside. Unit is shut off. Grounded compressor,burnt R-410A .Burnt contactor. System needs evaluation before any repairs attempted.
Shawn C.
Complaint no a/c Replaced bad capacitor
Shawn C.
Complaint no a/c Added 4 lbs of r22 to Goodman on one side upfront and 3.5 lbs to unit on the other side up front, I’m not familiar with the way these are labeled so not sure which equip I should tag to. Steve is coming later to add leak stop
Shawn C.
AC Not Cooling - Low on freon Unit is flat out of gas. No action to be taken at this time. Gave customer some options.