Goreville IL AC and Heating Experts
Charlie’s Air Conditioning & Heating has been warming and cooling Southern, IL homes and businesses for almost 40 years. We’ve been serving Goreville, IL and the surrounding areas since 1982.
Read our fantastic reviews and find out why your Southern, IL neighbors consider us to be their nearby heating and air company in Goreville, IL.
Local Reviews
for Goreville, IL
Our Reviews by City
We payed 165.00 in the spring for checkup of heating and air. When they came back for the air they said a capacitor has a slight crack in it. Recommen
Tim - Goreville, IL
Way too expensive
Excellent service
Tim - Goreville, IL
Steve was awesome. Very friendly and knowledgeable
Bent over by the furnace
Phyllis - Goreville, IL
I woke up hot and sticky yesterday so I called the gang down at Charlie’s. Daniel came straight over and got my apartment cooled down…….but not me! After he had been bent over by the furnace for awhile, it took a glass of lemonade to cool us both down. Daniel was there all afternoon servicing my needs and then some. He is a very thorough and thoughtful young man. I would highly recommend him to all my gals. Sincerely, Phyllis
Daniel B.
PCSA 2022 Prepaid AC Check Up Hard start capacitor on outdoor coil was cracked and showing signs of wear. Replaced hard start. Everything else was clean and checked out well. System is operating normally at this time.
Daniel B.
PCSA 2022 a/c check up prepaid Everything was clean and checked out well. System is operating normally at this time.
Daniel B.
2022 Spring Check Up PCSA Prepaid Everything was clean and checked out well. System is operating normally at this time.
Pete F.
Gave quote to replace AC unit
Phil P.
Ckd codes on new furnace, ok. Washed condenser. Noted mice issue.
Daniel B.
PCSA AC ONLY Check Up Hard start capacitor on outdoor coil was leaking oil everywhere. Replaced hard start. Everything else was clean and checked out well. System is operating normally at this time.
Steve R.
Inspect system operation and check charge on new install
Steve R.
Furnace Repair - Complaint furnace not operating properly, found drain backed up. Cleaned drain, checked furnace signed up pcsa. Used first visit today, need to call tomorrow to set up visit for April or early May.
Daniel B.
AC Repair - 2021 Fall Check Up PCSA Prepaid Capacitor on outdoor coil was getting very weak and needed replaced. Replaced capacitor. Hardstart is showing signs of corrosion but is still operational. Would recommend replacement during future check up. Everything else was clean and checked out well. System is operating normally at this time.
Steve R.
Auxiliary heat is running, found compressor not starting. Outdoor dual capacitor was reading weak, replaced part. Tested heat pump and air conditioning, checked charge, looked great. System is heating at this time
Daniel B.
No heat Cause of the issue was dirty flame sensor and dirty filter. Cleaned flame sensor on west system and replaced filters in both systems. Both are operating normally at this time.
Steve R.
Found possible leak in indoor coil. System was 3 lbs low on R-410A. Would recommend coil replacement in the near future. 12/21/21 Steve returned and replaced A-coil, pressure tested system, no leaks. Evacuated to 500 microns, tested heat, electric heat and ac. Added 10 oz r410a, system is heating
Pete F.
Gave quote to replace Ruud heat pump with York 15.75 SEER heat pump
Steve R.
Replaced primary control board, G lug was stripped out out of the box on the old one. System is heating
Steve R.
Was at house next door, walked over and told them where to get an igniter
Steve R.
Installed power bar with fuses that customer supplied, tested heat it’s working correctly
Daniel B.
2021 Fall Check Up PCSA Paid Complaint no heat. Cause of the issue was bad thermostat. Replaced thermostat and checked system operation. Everything else was clean and checked out well. System is operating normally at this time.
Shawn C.
Complaint gas furnace blowing cold air Unit running now but blower limit acting funky. Wiggled the series wires to it and got it to run. Limit most likely failing or terminals corroded. Dab collected for now model and serial in picture to check on ordering new limit
Pete F.
During System maintenance found Carbon Monoxide in flue pipe over 100 ppm. Flue CO levels were much higher than last heating check up. To rule out improper fuel/air mixture we checked flues for obstructions in flue piping and cleaned burners. CO levels were still high. CO due to cracked Heat exchanger. Furnace replacement needed.
Steve R.
PCSA 2021 RENEWAL - Heating Check Up Tested electric heat, checked all connections, tested fan, cleaned air handler, cleaned filter, vacuumed return, tested heat pump, checked charge, system is working great
Phil P.
Filled out form.
Steve R.
Unit Frozen Up Unit satisfied at 69 upon arrival very dirty filters, removed, checked charge system is cooling, tenant will get new ones
Pete F.
Quote for new system
Daniel B.
Water in floor 2021 Spring AC Check Up PCSA Cause of the issue was clogged drain line. Everything else was clean and checked out well. System is operating normally at this time.