Goreville IL AC and Heating Experts
Charlie’s Air Conditioning & Heating has been warming and cooling Southern, IL homes and businesses for almost 40 years. We’ve been serving Goreville, IL and the surrounding areas since 1982.
Read our fantastic reviews and find out why your Southern, IL neighbors consider us to be their nearby heating and air company in Goreville, IL.
Local Reviews
for Goreville, IL
Our Reviews by City
Great service and great staff
Ray - Goreville, IL 62939
Service call
Sims - Goreville, IL 62939
Great great customer service!!! Daniel B is a top notch representative of your business. Charging 200$ for a 15$ transformer 🤷♂️
We payed 165.00 in the spring for checkup of heating and air. When they came back for the air they said a capacitor has a slight crack in it. Recommen
Tim - Goreville, IL 62939
Way too expensive
Excellent service
Tim - Goreville, IL 62939
Steve was awesome. Very friendly and knowledgeable
Bent over by the furnace
Phyllis - Goreville, IL 62939
I woke up hot and sticky yesterday so I called the gang down at Charlie’s. Daniel came straight over and got my apartment cooled down…….but not me! After he had been bent over by the furnace for awhile, it took a glass of lemonade to cool us both down. Daniel was there all afternoon servicing my needs and then some. He is a very thorough and thoughtful young man. I would highly recommend him to all my gals. Sincerely, Phyllis
Daniel B.
Cause of the issue was the sequencer was stuck on preventing at least one of the heat strips from shutting off. Replaced sequencer and checked system operation multiple times. System appears to be operating normally at this time.
Daniel B.
Inspected system and found multiple reasons for way furnace was overheating. Indoor coil was dirty and needed cleaned. Several of the fins are damaged beyond repair but it seems to be allowing proper air flow through. Blower wheel was filled with hair and debris. Cleaned flower wheel. Blower motor was also FULL of debris beyond salvageable. Bearings inside motor were also heavily worn. Replaced blower motor. Cleaned out furnace flue which had at least one dead mouse inside. Air return is also too small for system which means system cannot use pleated filters and operate normally. System is going to need fiberglass filters only. 10x20x1 and 12x20x1. System is operating normally at this time.
Pete F.
Heat Pump install
Daniel B.
Cause of the issue was a tripped limit on the furnace. Reset limit and monitored furnace operation. System ran for over 20 minutes with no issues. Replaced filters as well. System was operating normally at this time. Tenant will monitor system for any changes in operation.
Pete F.
Heat Pump Install Goreville
Justin T.
Replaced condenser fan motor and verified operation of system.
Daniel B.
Complaint: No Heat complaint older unit by pool kicking on and off. Cause of the issue was a short on the outdoor coil. Repaired short. Transformer was also dead and thermostat wouldn’t send a signal out for G. Replaced transformer and thermostat. System is operating normally at this time. Customer would like to sign up for a service plan again.
Daniel B.
2022 Fall Check Up PCSA Free with Install Complaint emergency heat running all the time. Cause of the issue was system was tripping on high pressure. Adjusted pressure and system appears to be operating normally. Would like to double check pressures in Spring in AC mode.
Shawn C.
Replaced filter with left over from install. Dialed gas pressure as high as it would go at about 9” WC. My guess is incoming pressure is a tad low but this is still suitable to heat house adequately. All other checks good
Daniel B.
PCSA 2022 Heating Check Up Renewal Everything was clean and checked out well. System is operating normally at this time.
Daniel B.
2022 Fall Check Up PCSA Free Control board was free of codes. Everything was clean and checked out well. System is operating normally at this time.
Shawn C.
Replaced condensing unit and metering device
Justin T.
AC Not Cooling - DOOR UNLOCKED. System was low on R410A. Started to add refrigerant and once I got to 3lbs I could hear a leak. Looked inside system and could see oil on the piping. Discovered end loop/feeding tube going into the field of coil, 4 loops up from bottom of condenser on servicing corner, is corroding off. Condenser coil needs to be replaced due to placement of leak.
Daniel B.
Complaint not keeping up. Customer canceled appointment.
Justin T.
Outdoor condenser unit has a bad fan motor and was locked up and over amping. Replaced with new motor and verified operation. Amperage checks out good and system is cooling efficiently.
Daniel B.
Cause of the issue was bad blower motor. Replaced blower motor and capacitor. System is operating normally at this time.
Daniel B.
Complaint no a/c the unit was blowing out warm air t-stat was set @ 77* and it was 98* in apartment. Cause of the issue was a bad connection on the reversing valve which was causing the system to go from AC to Heat Pump mode randomly. Redid connection and system appears to be operating normally at this time.
Daniel B.
2020 AC Check Up Renewed & Done 6/9/20 2020 Heating Check Up Prepaid & Done 10/12/20 2021 AC Check Up Renewed & Done 7/15/21 2021 Heating Check Up Prepaid & Done 2/21/22 2022 AC Check Up Renewal Blower capacitor and outdoor coil capacitors were both very weak and needed replaced. System needed close to 1 lb of R-22 to work at peak efficiency. Everything else was clean and checked out well. System is operating normally at this time. Cause of high electric bill appears to be poor insulation inside manufactured home walls and ceiling. Didn’t see any signs of damaged duct work under the house causing air loss based on a quick glance.
Daniel B.
2022 Spring Check Up PCSA New Outside Unit not coming on after power failure yesterday. Cause of the issue was bad capacitor on outdoor coil. Replaced capacitor. System needed 1 lb of R-22. Customer wanted to sign up for service plan. Would recommend replacing contactor on outdoor coil next AC check up. Everything else was clean and checked out well. System is operating normally at this time.
Daniel B.
AC not cooling. Replaced filter and cleaned outdoor coil for full air flow. System could be slightly overcharged. None of the electric heaters were on. Lowered blower speed and checked temperatures and pressures. Temperature drop is about 17 degrees. System appears to be operating normally at this time. Tenant will monitor for any changes in operation.
Daniel B.
Water issue. Cause of the issue was clogged drain line. Cleaned drain line and vacuumed water out of return. Filter was replaced recently, temperature drop is within range, and pressures look normal. System is operating normally at this time.
Gerson C.
Replaced t-stat, 2015 install
Justin T.
PCSA 2022 RENEWAL - AC Check Up. System checks out good and is running efficiently, filters are changed and outdoor coil is clean
Daniel B.
PCSA 2022 Prepaid AC Check Up Hard start capacitor on outdoor coil was cracked and showing signs of wear. Replaced hard start. Everything else was clean and checked out well. System is operating normally at this time.
Daniel B.
PCSA 2022 a/c check up prepaid Everything was clean and checked out well. System is operating normally at this time.