Pittsburg IL AC and Heating Experts
Charlie’s Air Conditioning & Heating has delivered Pittsburg, IL excellent service for almost 40 years. We specialize in heating and air conditioning services as well as blown-in insulation.
Check out our glowing reviews and discover why your neighbors consider us to be their nearby heating and air company in Pittsburg, IL.
Local Reviews
for Pittsburg, IL
Our Reviews by City
Excellent service as usual
Ray - Pittsburg, IL 62974
Very thorough
Ray - Pittsburg, IL 62974
Great service and very professional.
Robert - Pittsburg, IL 62974
Furnace tune up😁
Stacey - Pittsburg, IL 62974
Wonderful service and on time. I’m so happy with the service
Melody - Pittsburg, IL 62974
Very friendly and respected. Fast service and reliable. Love the company, have told friends about you
Melody - Pittsburg, IL 62974
Great Service
Stacey - Pittsburg, IL 62974
Great job. Very professional.
Forward thinking comes to mind along with professionalism. Daniel did a wonderful job. Thanks again
Jim - Pittsburg, IL 62974
Daniel B.
Heating Maintenance PCSA 2023 Heating Check Up Renewal Dual Fuel System customer wanted to hold off on servicing the garage unit this season. Control board was free of codes. Cleaned flame sensor. Cleaned drain lines. Checked wire connections. Gas pressures were normal. Puron levels were within range. Outdoor coil was clean. Replaced filter. Everything was clean and checked out well. System is operating normally at this time.
Daniel B.
AC Maintenance PCSA 2023 AC Check Up Free w/ Install Replaced filter. Flushed drain lines. Checked wire connections. Puron levels were within range. Temperature drop upon arrival was around 30 degrees. Turned up blower speed and temperature drop is now closer to 24 degrees putting it closer to being within range. System is operating normally at this time.
Daniel B.
PCSA 2023 AC Check Up Free w/ Install Temperature drop is 20 degrees and pressures appear normal. Everything was clean and checked out well. System is operating normally at this time. Noticing section of duct work sweating above the unit. Recommending sealing with reflective insulation when possible.
Gerson C.
PCSA 2023 PREPAID AC CHECK UP Completed Spring maintenance, cleaned coils, flushed drain, filter is in good condition, checked air temps, checked blower amps Checked compressor and outdoor fan amps, checked capacitor, made sure system is working properly System is cooling at this time
Daniel B.
Heat Pump Repair Complaint: Unit freezing up. Turned down blower speed to help with temperature rise. Also removed 1 lb of R-410A to help compensate for blower adjustment. Temperature rise was at least 21 degrees. Puron levels appear to be normal. Checked both ambient and defrost sensors to make sure they were reading correct temperatures. Both seem to be operating normally at this time.
Daniel B.
Furnace Repair Complaint: Furnace not always coming on. Cause of the issue was dirty burners. Cleaned burners and flame sensor. Furnace appears to be operating normally. Humidifier needs a new pad when possible.
Daniel B.
Adjusted charge to have pressures operate normally. System is operating normally at this time.
Pete F.
Furnace Install
Shawn C.
Heating Repair - Limit error recorded, temp rise looks high in low fire, adjusted blower speed up one in low fire. Temp rise now at about 50 degrees in low fire. Unit heating at this time. Codes cleared
Steve R.
Replaced limit, turned off breaker and capped wires coming from the breaker with the 10 gauge wire. Started heat, everything is working correctly
Daniel B.
PCSA 2022 a/c check up prepaid replaced panel on outdoor cond. coil
Shawn C.
Complaint No Heat - Unit not coming on and performed the 2022 Heating Maintenance All maintenance performed. Heat pump not showing any issues at this time. Brad will monitor. Had a filter for the house but not for the barn. Barn filter is dirty and still needs replaced. All checks good on both furnaces and heat pump
Pete F.
Gave quote for 3 ton heat pump installation
Steve R.
AC Check Up cleaned condenser, flushed drain, inspected all electrical, replaced bad dual capacitor, checked charge, system is cooling. Need to come back with a filter
Gerson C.
Replaced bad blower capacitor . Unit in very poor condition. 2 of 3 heater work
Steve R.
Check up on furnace, cleaned furnace, turned on gas, cycled furnace, inspected ductwork, burners are rusted, need to get price on new ones. Wants ventless heater gas line hooked up, will do that when we replace burners. Replaced burners, ran gas line to heater, Jeff will get the fittings we need and call Returned 11/6 and hooked up heater
Steve R.
AC Check Up, flushed drain, cleaned furnace, washed condenser, cleaned off pad, checked charge system cooling great
Daniel B.
Broken spade terminal to capacitor. Warranty
Daniel B.
Replaced condenser fan motor, fixed burnt element wire. Tested heat pump and defrost. Replaced 30A breaker with 60A, wired up another heater. Found defrost not kicking in, need a defrost sensor. Replaced defrost swt.
Steve R.
Solenoid energized but not opening, need to order a new one Honeywell true ease HE300A1005 Replaced solenoid, cleaned drain line, humidifier pumping and draining correctly
Daniel B.
Complaint: Gas furnace not heating Dead blower. Replaced blower Run checks okay.
Shawn C.
2020 PCSA Heating Check Up Renew
Daniel B.
Installed iWave air purifier Capacitor on blower motor was also weak and needed replaced.