AC and Heating Experts in Colp IL
Charlie’s Air Conditioning & Heating has delivered Colp, IL excellent service for almost 40 years. We specialize in heating and air conditioning services as well as blown-in insulation.
Check out our glowing reviews and discover why your neighbors consider us to be their nearby heating and air company in Colp, IL.
Local Reviews
for Colp, IL
Our Reviews by City
Great Service
Yates - Colp, IL 62921
Justin was very professional and personal. Another example of the great service and wonderful staff at Charlie’s!
Great service, quality, and prices
Yates - Colp, IL 62921
Very professional and courteous. Always great
Excellent customer service and care!
Yates - Colp, IL 62921
Great service, very personable and extremely efficient
Yates - Colp, IL 62921
Paul
Yates - Colp, IL 62921
Awesome, expert service. I never allow anyone but Charlie’s to service my heating/cooling equipment.
Daniel B.
PCSA 2022 Heating Check Up Prepaid<br> Everything was clean and checked out well. System is operating normally at this time.
Justin T.
PCSA 2022 Heating Check Up Renewal. Both gas furnaces are heating efficiently at this time. Downstairs filter is changed, upstairs filter is changed as needed by customer. Temperature rises are acceptable, all hoses and drains are clear, and flame sensors are clean.
Justin T.
Pcsa 2022 heating check up
Shawn C.
Complaint: No Heat Need to order pressure switch. Manometer achieving .62 every time pressure switch calls for .3 and will intermittently open while in sequence of operations. 11/02/22 furnace fired 4 times in a row after pressure switch replaced. Unit heating at this time.
Gerson C.
Complaint customer thinks a/c low on freon. Added R-22 by superheat.
Steve R.
We are waiting on his coil. His house is 84. Check freon for him to get him cooling. Added 2 lb 410. Replaced coil and recharged system. System is operating normally at this time.
Shawn C.
NO AC - Not Blowing Air ReplCed bat thermostat and bad contactor
Daniel B.
NO AC - Heard a sound like a line blew. System was completely out of Puron upon arrival. Added nitrogen to system to try to track down leak. Leak is massive and most likely inside flex lineset. Leak may also be inside indoor coil but not seeing any signs of oil. A full leak search would need to be scheduled for a more exact location. Gave customer an estimate around $2000 for replacement of lineset. Left outdoor coil disconnect off and service valves closed.
Shawn C.
Complaint no a/c Found leak in evaporator coil. Needs replaced under warranty , model and serial in system. Added another lb of 410A
Justin T.
PCSA 2022 a/c check up renewal. System was not running up to full efficiency at time of arrival due to dirty condenser coil and low on R410A. Cleaned coil and added 1lb of R410A. is running efficiently at this time, drain is flushed and filter is changed.
Gerson C.
No AC - Outside unit kicks off then won't come back on . Bug in contactor switch.
Daniel B.
PCSA 2022 a/c check up prepaid 2 system South system needed 1 lb of R-22. Everything else was clean and checked out well. Both systems are operating normally at this time.
Daniel B.
PCSA 2022 a/c check up Everything was clean and checked out well. System is operating normally.
Gerson C.
Topped off charged by superheat. No warranty until leak is repair , which would not be economical.
Shawn C.
Heat & AC Repair Contractor - PCSA 2022 a/c maintenance renewal
Steve R.
Complaint no heat, found pressure switch going bad, replaced, need to order and return with correct pressure switch Returned and replaced psi switch with correct one. Replace swt. 1.60
Gerson C.
Made Beasley repair, removed black iron pipe installed flex. Ckd orifice hight . Opened plug on right side furnace for more combustion air 4 code #7
Daniel B.
2021 Fall Check Up PCSA Control board was free of codes. Everything was clean and checked out well. System is operating normally at this time.
Gerson C.
Complaint no heat . Sealed around ind. mtr. Gasket, remade connections to limit water at flame sensor.
Gerson C.
Unit off on code #4 all vents covered or closed
Steve R.
Complaint no heat, unit was locked out on a code 7. Cleaned flame sensor, checked and adjusted gas pressure, was at 2.4â€. Cleared code, cycled furnace, system is heating
Shawn C.
Complaint a/c is freezing up I warned customer that this thing doesn’t have long. Head pressure way up at 400. Most likely embedded coil or impending load failure or both Unit is cooling at this time after adding 1 lb of r-22
Daniel B.
Complaint unit short cycling Cause of the issue was bad thermostat. Replaced thermostat. System is operating normally at this time.
Gerson C.
PCSA 2021 a/c maintenance prepaid . Cleaned condenser removed side panels &washed. Cleaned drain.
Shawn C.
PCSA 2021 RENEWAL AC MAINTENANCE Equipment in system Filter changed provided by homeowner Drain flushed Target of 18 degrees +/- 5 SH of 14 degrees All checks good Mrs. Jackson will stop by the office and pay her bill